DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LC010D 데이터 시트보기 (PDF) - Tyco Electronics

부품명
상세내역
제조사
LC010D Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
LC/LW010- and LC/LW015-Series Power Modules:
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W
Data Sheet
August 1998
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Parameter
Device Symbol Min
Input Voltage:
Continuous
Transient (100 ms)
LC
VI
0
LW
VI
0
LW
VI, trans
0
Operating Case Temperature
All
(See Derating Curves, Figures 4345.)
TC
40
Storage Temperature
All
Tstg
55
I/O Isolation
All
Typ
Max
Unit
50
Vdc
80
Vdc
100
V
105*
°C
125
°C
1500
Vdc
* Maximum case temperature varies based on power dissipation. See derating curves, Figures 4345, for details.
Electrical Specifications
Table 1. Input Specifications
Parameter
Device Symbol Min
Typ
Max
Unit
Operating Input Voltage
LC
VI
18
LW
VI
36
Maximum Input Current
LC
II, max
(VI = 0 to VI, max; IO = IO, max; see Figures
LW
II, max
14.)
Inrush Transient
All
I2t
Input Reflected-ripple Current
All
II
(5 Hz to 20 MHz; 12 µH source imped-
ance; TA = 25 °C; see Figure 33.)
Input Ripple Rejection (100 Hz120 Hz) All
24
36
Vdc
48
75
Vdc
1.6
A
800
mA
0.2
A2s
5
mAp-p
45
dB
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow, dc fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturers data for further information.
2