DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MC-4516CA727XFA 데이터 시트보기 (PDF) - Elpida Memory, Inc

부품명
상세내역
제조사
MC-4516CA727XFA Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MC-4516CA727XFA
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Parameter
Symbol
Test condition
Operating current
ICC1 Burst length = 1
tRC tRC(MIN.), IO = 0 mA
/CAS latency = 2
/CAS latency = 3
Precharge standby current in
ICC2P CKE VIL(MAX.), tCK = 15 ns
power down mode
ICC2PS CKE VIL(MAX.), tCK =
Precharge standby current
in non power down mode
Active standby current in
ICC2N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
Input signals are changed one time during 30 ns.
ICC2NS CKE VIH(MIN.), tCK =
Input signals are stable.
ICC3P CKE VIL(MAX.), tCK = 15 ns
power down mode
ICC3PS CKE VIL(MAX.), tCK =
Active standby current in
non power down mode
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
Input signals are changed one time during 30 ns.
Operating current (Burst mode)
ICC3NS CKE VIH(MIN.), tCK = ,
Input signals are stable.
ICC4 tCK tCK(MIN.), IO = 0 mA
/CAS latency = 2
/CAS latency = 3
CBR (Auto) refresh current
ICC5
tRC tRC(MIN.)
/CAS latency = 2
/CAS latency = 3
Self refresh current
ICC6 CKE 0.2 V
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
High level output voltage
VOH IO = – 4 mA
Low level output voltage
VOL IO = + 4 mA
-A75
MIN. MAX.
900
945
9
9
180
Unit Notes
mA 1
mA
mA
72
45
mA
36
270 mA
180
1,080 mA 2
1,395
2,070 mA 3
2,160
18
mA
–9
+9
µA
– 1.5 + 1.5 µA
2.4
V
0.4
V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6
Data Sheet E0231N20 (Ver. 2.0)

Share Link: 