RFD14N06L, RFD14N06LSM, RFP14N06L
Typical Performance Curves (Continued)
800
VGS = 0V, FREQUENCY (f) = 1MHz
50
CISS
600
10
400
STARTING TJ = +25oC
COSS
200
CRSS
0
0
5
10
15
20
25
VDS, DRAIN-TO-SOURCE VOLTAGE (V)
FIGURE 13. TYPICAL CAPACITANCE vs VOLTAGE
STARTING TJ = +150oC
If R = 0
tAV = (L)(IAS)/(1.3*RATED BVDSS - VDD)
If R ≠ 0
tAV = (L/R)ln[(IAS*R)/(1.3*RATED BVDSS-VDD) +1]
1
0.01
0.1
1
10
tAV, TIME IN AVALANCHE (ms)
FIGURE 14. UNCLAMPED INDUCTIVE SWITCHING. REFER TO
HARRIS APPLICATION NOTES AN9321 AND
AN9322
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0
25
50
75
100
125
150
175
TC, CASE TEMPERATURE (oC)
FIGURE 15. NORMALIZED POWER DISSIPATION vs TEMPERATURE DERATING CURVE
5