DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

IDT74FCT573CTEB 데이터 시트보기 (PDF) - Integrated Device Technology

부품명
상세내역
제조사
IDT74FCT573CTEB
IDT
Integrated Device Technology IDT
IDT74FCT573CTEB Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
IDT54/74FCT373T/AT/CT/DT - 2373T/AT/CT, IDT54/74FCT533T/AT/CT, IDT54/74FCT573T/AT/CT/DT - 2573T/AT/CT
FAST CMOS OCTAL TRANSPARENT LATCHES
MILITARY AND COMMERCIAL TEMPERATURE RANGES
POWER SUPPLY CHARACTERISTICS
Symbol
ICC
ICCD
IC
Parameter
Quiescent Power Supply Current
TTL Inputs HIGH
Dynamic Power Supply
Current(4)
Total Power Supply Current(6)
Test Conditions(1)
VCC = Max.
VIN = 3.4V(3)
VCC = Max.
VIN = VCC FCTxxxT
Outputs Open
OE = GND
VIN = GND
FCT2xxxT
One Input Toggling
50% Duty Cycle
VCC = Max.
VIN = VCC FCTxxxT
Min. Typ.(2) Max.
— 0.5 2.0
— 0.15 0.25
— 0.06 0.12
— 1.5 3.5
Unit
mA
mA/
MHz
mA
Outputs Open
fi = 10MHz
50% Duty Cycle
OE = GND
LE = VCC
One Bit Toggling
VCC = Max.
VIN = GND FCT2xxxT —
VIN = 3.4 FCTxxxT —
VIN = GND
FCT2xxxT
VIN = VCC FCTxxxT
0.6 2.2
1.8 4.5
0.9 3.2
3.0 6.0(5)
Outputs Open
VIN = GND FCT2xxxT —
1.2 3.4(5)
fi = 2.5MHz
50% Duty Cycle
OE = GND
VIN = 3.4 FCTxxxT
5.0 14.0(5)
VIN = GND
LE = VCC
FCT2xxxT —
3.2 11.4(5)
Eight Bits Toggling
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 5.0V, +25°C ambient.
2564 tbl 09
3. Per TTL driven input (VIN = 3.4V). All other inputs at VCC or GND.
4. This parameter is not directly testable, but is derived for use in Total Power Supply Calculations.
5. Values for these conditions are examples of the ICC formula. These limits are guaranteed but not tested.
6. IC = IQUIESCENT + IINPUTS + IDYNAMIC
IC = ICC + ICC DHNT + ICCD (fCP/2 + fiNi)
ICC = Quiescent Current
ICC = Power Supply Current for a TTL High Input (VIN = 3.4V)
DH = Duty Cycle for TTL Inputs High
NT = Number of TTL Inputs at DH
ICCD = Dynamic Current Caused by an Input Transition Pair (HLH or LHL)
fCP = Clock Frequency for Register Devices (Zero for Non-Register Devices)
fi = Input Frequency
Ni = Number of Inputs at fi
All currents are in milliamps and all frequencies are in megahertz.
6.12