M62295GP
Formula for light control level by light control voltage
ON Duty = (100 − ON Duty Min) ×
2.4 − VAdj2
2.4
+ ON Duty Min (%)
VAdj2: Adj2 terminal voltage (V)
ON Duty Min = 10 (%)
G1 output
G2 output
CT2 waveform
Figure 6 (a) 100% Light Control
G1 output
G2 output
CT2 waveform
Figure 6 (b) 50% Light Control
G1 output
G2 output
CT2 waveform
Figure 6 (c) 10% Light Control
REJ03D0856-0201 Rev.2.01 Nov 14, 2007