V11
Specifications
ALD Derating Curve
All specifications are Typical at nominal line, full load and 25˚C unless otherwise noted
INPUT SPECIFICATIONS:
Input Voltage …….……..…… 1400mA/other …...... 6-40VDC/6-50Vdc
Input Surge Voltage (1second) … 1400mA/other ….. 50Vdc/65Vdc max.
Input Filter …………………………………………….…………. Capacitor
Under Voltage Lockout ………….… Power up …………..… 4.2Vdc typ.
Power down …………. 3.8Vdc typ.
OUTPUT SPECIFICATIONS:
Constant Current Accuracy (note1) ..……………..…….……… ±5% max.
Current Line Regulation (note2) ……………….………..……. ±5% max.
Current Load Regulation (note3) ..…………….………..………. ±5% max.
Short Circuit Protection …..…….. Constant Current with Auto Recovery
Start up time …………………………………………………… 60ms max.
GENERAL SPECIFICATIONS:
Efficiency ……………………………….…………………………. See Table
Temperature Coefficient ……….............….…..…… ±0.05%/(0-50)
Isolation Voltage ………………………………………..……. Non-isolation
Switching Frequency ..….…………………………..……….. 500KHz typ.
Operating Ambient Temperature …......... -40~75see Derating Curve
Case Temperature ................................................................. 100max.
Cooling …………………………………………..……. Natural Convection
Storage Temperature ……...………....………………........... -55-125
Operating Humidity …………………….… 10%~95%RH non-condensing
Operating Altitude …………….…………………..…. Sea Level to 3000m
Shock/Vibration ………………………………………….… MIL-STD-810F
MTBF ………… MIL-HDBK-217F/25..……………..…. 700Khrs typ.
Dimensions ….…...... Other: 1.60x0.93x0.40 Inches(40.6x23.5x10.1mm)
T:2.354x1.339x0.646 Inches(59.80x34.01x16.40mm)
Weight ……………………..… PIN/LW/T ………………… 18g/23g/30g
Case Material ………………………..……………………….. Plastic Case
DALI Control:
Output Current Dimming Range ……..………………..……….. 5%-100%
SAFETY AND EMISSIONS:
EMI ………...………………......……............ EN55022/EN55015 Class B
EMS ………......................................... EN61547,EN61000-4-2, 3, 4, 5, 6
Mechanical Specification
120
-40.0
100
60 70 75
80
60
350mA
500mA
40
700mA
1050mA
20
1400mA
0
-40 -20 0 20 40 60
Ambient Temperature()
ALD-DXXX(LW)
80 100
120
-40.0
100
45 55 65 70
80
60
350mA
500mA
40
700mA
1050mA
20
1400mA
0
-40
-20 0 20 40 60
Ambient Temperature()
ALD-DXXXT
80 100
NOTE:
1. 3V<Vin-Vout<30Vdc to keep current accuracy.
2. Current line regulation is measured from high line to low line.
3. Current load regulation is measured from high to low operating voltage.
4. Suffix ”LW” to the model number with wire type.
5. Suffix” T” to the model number with terminal type and only meets IP20
Terminal: WAGO 250-108 or equivalent; wire range: 16~20 AWG.
6. Acceptable customer modifications.