Electrical Performance (Continued)
ART28XXT Series
Parameter
Symbol
Conditions
MIN
MAX Units
Enable Input
open circuit voltage
drive current (sink)
voltage range
3.0
5.0
V
0.1
mA
-0.5
50.0
V
Synchronization Input
frequency range
pulse high level
pulse low level
pulse rise time
pulse duty cycle
Synchronization Output
pulse high level
pulse low level
External clock signal on Sync. input (pin 4)
Signal compatible with synchronization input
225
310
KKHhzz
4.5
10.0
V
-0.5
0.25
V
40
V/µSs
20
80
%
3.7
4.3
V
0.0
0.25
Power dissipation, load fault
Output response to step load
changes Notes 7, 11
Recovery time from step load
changes Notes 11, 12
PD
Short circuit, any output
10% Load to/from 50% load
VTLD 50% Load to/from 100% load
10% Load to/from 50% load
TTLD 50% Load to/from 100% load
-200
-200
16
W
200
200
mVPK
200
200
µµsS
Output response to step line
changes Notes 10, 11
Recovery time from step line
changes Notes 10, 11,13
Turn on overshoot
Turn on delay Note 14
Capacitive load Notes 9, 10
VTLN
TTLN
IOUT = 3000 mAdc
VIN = 19 V to/from 50 V
IOUT = ±500 mAdc
IOUT = 3000 mAdc
VIN = 19 V to/from 50 V
IOUT = ±500 mAdc
VOS
IOUT = minimum and full rated
TDLY IOUT = minimum and full rated
CL No effect on DC performance
(main)
(dual)
(main)
(dual)
(main)
(dual)
(main)
(dual)
-350
-1050
5.0
350
1050
500
500
100
500
20
500
100
mVPK
µµsS
mV
mSs
µF
Isolation
ISO 500VDC Input to Output or any pin to case
100
M
(except pin 12)
Notes to SPECIFICATIONS
1. Operation outside absolute maximum/minimum limits may cause permanent damage to the device. Extended operation at the limits may permanently
degrade performance and affect reliability.
2. Device performance specified in Electrical Performance table is guaranteed when operated within recommended limits. Operation outside
recommended limits is not specified.
3. Parameter measured from 28V to 19 V or to 50V while loads remain fixed.
4. Parameter measured from nominal to minimum or maximum load conditions while line remains fixed.
5. Up to 750 mA is available from the dual outputs provided the total output power does not exceed 30W.
6. Guaranteed for a bandwidth of DC to 20MHz. Tested using a 20KHz to 2MHz bandwidth.
7. Load current is stepped for output under test while other outputs are fixed at half rated load.
8. Load current is fixed for output under test while other output loads are varied for any combination of minimum to maximum.
9. A capacitive load of any value from 0 to the specified maximum is permitted without comprise to DC performance. A capacitive load in excess of the
maximum limit may interfere with the proper operation of the converter’s short circuit protection, causing erratic behavior during turn on.
10. Parameter is tested as part of design characterization or after design or process changes. Thereafter, parameters shall be guaranteed to the limits
specified in the table.
11. Load transient rate of change, di/dt 2 A/µSec.
12. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of its steady state value.
13. Line transient rate of change, dv/dt 50 V/µSec.
14. Turn on delay time is for either a step application of input power or a logical low to high transition on the enable pin (pin 3) while power is present at the
input.