深圳市天微电子有限公司
SHENZHEN TI TAN M I CRO ELECTRONI CS CO. , LTD.
is highly recommended that an external pull-up resistor (1 KOhms to 10
KOhms) must be connected to DIO.
Reception (Data/Command Write)
ONLY 1 BYTE
If data
continues
Transmission (Data/Read)
Data Read Command is set
Data Reading starts
where: twait (waiting time) > 1µs
It must be noted that when the data is read, the waiting time(t ) wait
between the rising of the eighth clock that has set the command and the
falling of the first clock that has read the data is greater or equal to 1µ s.
SWITCHING CHARACTERISTIC WAVEFORM
TM1628 Switching Characteristics Waveform is given below.
Add:522,5/F,Bldg. No.4,Keji Central Road 2, Software Park,High-Tech Industrial Park,Shenzhen
Tel:86-755-86185092
Fax: 86-755-86185093
Web: www.titanmec.com
7