M58LW032D
Figure 13. Reset, Power-Down and Power-Up AC Waveform
W
E2, E1, E0(1), G
tPHWL
DQ0-DQ15
STS
(Ready/Busy mode)
tPHQV
RP
VDD, VDDQ
tVDHPH
Power-Up
and Reset
tPLBH
tPLPH
Reset during
Program or Erase
AI06217b
Note: 1. VIH = Device Disabled (first edge of E0, E1 or E2), VIL = Device Enabled (first edge of E0, E1 or E2). Refer to Table 2. for more
details.
Table 19. Reset, Power-Down and Power-Up AC Characteristics
Symbol
Parameter
M58LW032D
90
110
Unit
tPHQV Reset/Power-Down High to Data Valid
Max 130
150
ns
tPHWL Reset/Power-Down High to Write Enable Low
Max
1
1
µs
tPLPH Reset/Power-Down Low to Reset/Power-Down High
Min 100
100
ns
tPLBH Reset/Power-Down Low to Status/(Ready/Busy) High
Max 30
30
µs
tVDHPH Supply Voltages High to Reset/Power-Down High
Min
0
0
µs