Electrical Specifications Test Conditions: V+ = +5V, V- = -5V, VREF = -10V, TA = 25oC, fCLK = 500kHz, Unless Otherwise Noted
PARAMETER SYMBOL
TEST
CONDITIONS
J
K
L
MIN TYP MAX MIN TYP MAX MIN TYP MAX UNITS
High State
VIH
Input Voltage
TMIN -TMAX 2.4
-
-
2.4 -
-
2.4 -
-
V
Logic Input
Current
ILIH
0 < VIN < V+
-
1
10
-
1
10
-
1
10
µA
Logic Input
CIN
Capacitance
-
15
-
-
15
-
-
15
-
pF
LOGIC OUTPUT
Low State Output VOL
Voltage
High State Output VOH
Voltage
Three-State Output IOX
Current
IOUT = 1.6mA
-
-
TMIN -TMAX
IOUT = -200µA
2.8
-
TMIN -TMAX
0 < VOUT < V+
-
1
0.4
-
-
0.4
-
-
0.4
V
-
2.8 -
-
2.8 -
-
V
-
-
1
-
-
1
-
µA
Logic Output
Capacitance
COUT Three-State
-
15
-
-
15
-
-
15
-
pF
POWER REQUIREMENTS
Supply Voltage
VSUPPLY Functional Operation Only ±4.5
-
±6.0 ±4.5 - ±6.0 ±4.5 - ±6.0
V
Range
Supply Current,
I+, I-
ISUPPLY
RM
-
2
4
-
2
4
-
2
4
mA
TMIN -TMAX
6
6
6
NOTES:
4. Full scale range (FSR) is 10V (reference adjusted).
5. Assume all leads are soldered or welded to printed circuit board.
6. “J” and “K” versions not production tested. Guaranteed by Integral Linearity Test.
7. Typical values are not tested, for reference only.
8. Not production tested. Guaranteed by design.
AC Electrical Specifications Test Conditions V+ = +5V, V- = -5V, TA = 25oC, fCLK = 500kHz, unless otherwise noted. Data
derived from extensive characterization testing. Parameters are not production tested
PARAMETER
TEST
SYMBOL
CONDITIONS
MIN
READ CYCLE TIMING
Propagation Delay CS to Date
t cd
RD Low, A0 Valid
-
Propagation Delay A0 to Data
t ad
CS Low, RD Low
-
Propagation Delay RD to Data
t rd
CS Low, A0 Valid
-
Propagation Delay Data to Three-State
t rx
-
Propagation Delay EOC High to Data
t ed
-
WRITE CYCLE TIMING
WR Low Time
t wr
150
Propagation Delay WR Low to EOC Low
t we
Wait Mode
1
EOC High Time
t eo
Free Run Mode
0.5
Conversion Time
t conv
-
Clock Frequency Range
f CLK
Functional Operation Only
-
NOTE:
9. All typical values have been characterized, but are not tested.
TYP
MAX UNITS
-
200
-
200
-
200
ns
-
150
-
200
-
-
ns
-
2
-
1.5 1/fCLK
-
20
500
-
kHz