S3C1840
TRANSMISSION CARRIER FREQUENCY
One of four carrier frequencies can be selected and transmitted through the P2.0/REM pin by programming the
internal P2.9, P2.10 and P2.0 pins (See Table 1-5). Figure 1-16 shows a simplified diagram of the various
transmission circuits.
P2.10
0
0
1
1
Table 1-5. Carrier Frequency Selection Table
P2.9
0
1
0
1
Carrier Frequency of P2.0/REM Pin
fxx/12, 1/3 duty
fxx/8, 1/2 duty
fxx/12, 1/4 duty
No carrier