DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M52743BSP 데이터 시트보기 (PDF) - Renesas Electronics

부품명
상세내역
제조사
M52743BSP Datasheet PDF : 26 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
M52743BSP
C.T.1 Crosstalk1 (f = 50 MHz)
Input SG3 (50 MHz) to pin 2 only, and then measure the waveform amplitude output at OUT (29, 32, 35). The
measured value is called VOUT (29, 32, 35). Crosstalk C.T.1 is calculated by the equation below:
VOUT (29, 32)
C.T.1 = 20log
(dB)
VOUT (35)
C.T.1' Crosstalk1 (f = 150 MHz)
Measuring condition and procedure are the same as described in C.T.1, expect SG3 to 150 MHz.
C.T.2 Crosstalk2 (f = 50 MHz)
Input SG3 (50 MHz) to pin 6 only, and then measure the waveform amplitude output at OUT (29, 32, 35). The
measured value is called VOUT (29, 32, 35). Crosstalk C.T.2 is calculated by the equation below:
VOUT (29, 35)
C.T.2 = 20log VOUT (32) (dB)
C.T.2' Crosstalk2 (f = 150 MHz)
Measuring condition and procedure are the same as described in C.T.2, expect SG3 to 150 MHz.
C.T.3 Crosstalk3 (f = 50 MHz)
Input SG3 (50 MHz) to pin 11 only, and then measure the waveform amplitude output at OUT (29, 32, 35). The
measured value is called VOUT (29, 32, 35). Crosstalk C.T.3 is calculated by the equation below:
VOUT (32, 35)
C.T.3 = 20log
(dB)
VOUT (29)
C.T.3' Crosstalk3 (f = 150 MHz)
Measuring condition and procedure are the same as described in C.T.3, expect SG3 to 150 MHz.
Tr Pulse Characteristics1 (4 VP-P)
Control the main contrast (00H) in order that the amplitude of output signal is 4.0 VP-P.
Control the brightness (V30) in order that the Black level of output signal is 2.0 V.
Measure the time needed for the input pulse to rise from 10% to 90% (Tr1) and for the output pulse to rise from 10% to
90% (Tr2) with an active probe.
Pulse characteristics Tr is calculated by the equations below:
Tr = [ (Tr2)2 (Tr1)2 ] (ns)
Tf Pulse Characteristics2 (4 VP-P)
Measure the time needed for the input pulse to fall from 90% to 10% (Tf1) and for the output pulse to fall from 90% to
10% (Tf2) with an active probe.
Pulse characteristics Tf is calculated by the equations below:
Tf = [ (Tf2)2 (Tf1)2 ] (ns)
100%
90%
0%
Tr1 or Tr2
REJ03F0193-0201 Rev.2.01 Mar 31, 2008
Page 11 of 25
10%
Tf1 or Tf2