DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

UC1608XFAC 데이터 시트보기 (PDF) - Unspecified

부품명
상세내역
제조사
UC1608XFAC Datasheet PDF : 42 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
ULTRACHIP
High-Voltage Mixed-Signal IC
©1999-2002
(9) Set Gain and Potentiometer
Action
C/D W/R D7 D6 D5 D4 D3 D2 D1 D0
Set Gain and Potentiometer
0010000001
GN [1:0] PM [5:0]
(Double byte command)
0 0 GN1 GN0 PM5 PM4 PM3 PM2 PM1 PM0
Program Gain (GN[1:0]) and Potentiometer (PM[5:0]). See section LCD VOLTAGE SETTING for more detail.
Effective range of GN = 0 ~ 3
PM value = 0 ~ 63
(10) Set RAM Address Control
Action
Set AC [2:0]
C/D W/R D7 D6 D5 D4 D3 D2 D1 D0
0 0 1 0 0 0 1 AC2 AC1 AC0
Program registers AC[2:0] for RAM address control.
AC[0] - WA, Automatic column/page wrap around.
0: CA or PA (depends on AC[1]= 0 or 1) will stop incrementing after reaching boundary
1: CA or PA (depends on AC[1]= 0 or 1) will restart, and PA or CA will increment by one step.
AC[1] – Auto-Increment order
0 : column (CA) increment (+1) first until CA reach CA boundary, then PA will increment by (+/-1).
1 : page (PA) increment (+/-1) first until PA reach PA boundary, then CA will increment by (+1) .
AC[2] – PID, page address (PA) auto increment direction ( 0/1 = +/- 1 )
When WA=1, controls whether page address will be adjusted by +1 or -1, when CA reached CA
boundary. No effect when WA=0.
CA boundary is 240 and PA boundary is 15 when PID=0, PA boundary is 0 when PID=1.
(11) Set All Pixel ON
Action
C/D W/R D7 D6 D5 D4 D3 D2 D1 D0
Set All Pixel On DC [1]
0 0 1 0 1 0 0 1 0 DC1
Set DC[1] to force all SEG drivers to output ON signals. This function has no effect on the existing data
stored in display RAM.
(12) Set Inverse Display
Action
C/D W/R D7 D6 D5 D4 D3 D2 D1 D0
Set Inverse Display DC [0]
0 0 1 0 1 0 0 1 1 DC0
Set DC[0] to force all SEG drivers to output the inverse of the data stored in display memory. This function
has no effect on the existing data stored in display RAM.
(13) Set Display Enable
Action
C/D W/R D7 D6 D5 D4 D3 D2 D1 D0
Set Display Enable DC[2]
0 0 1 0 1 0 1 1 1 DC2
This command is for programming registers DC[2].
When DC[2] is set to 0, the IC will put itself into Sleep mode. All drivers, voltage generation circuit and timing
circuit will be halted to conserve power. When DC[2] is set to 1, UC1608 will first exit from Sleep mode,
restore the power and then turn on COM drivers and SEG drivers. There is no other explicit user action or
timing sequence required to enter or exit the Sleep mode.